Affordable, Reliable and Accessible Technology.

Get in Touch : Fevziçakmak Mah. Aslım Cad. No:92/D
Karatay/Konya
42050 - TÜRKİYE
Tel: +90 507 897 79 66 Tel: +90 332 346 46 24 Tel: +90 507 897 79 66 info@superex.com.tr export@superex.com.tr

SUPEREX F-1000

Counterflow Supercritical Extraction System

F-1000
  • 1 Liter extractor column
  • Extra 0.5 liter extractor column,
  • With CO2 liquefaction system,
  • Working pressure up to 345 Bar,
  • Working temperature up to 70 °C,
  • All surfaces in contact with food are stainless steel,
  • Smooth-honed reactor columns against microbial attachments,
  • Special design for extraction from liquid sample,
  • Extra liquid feed pump,
  • Instant visible flow rate on the flowmeter,
  • Temperature control with PID algorithm,
  • Digital fully automatic pressure control,
  • Easy sample loading,
  • Independent electronic and mechanical pressure safety system,

Ürün Açıklaması

The F-1000 with 1 Liter main extractor column plus extra 0.5 liter extractor column is specially designed for extraction from liquid samples. Features extra liquid feed pump and instant visible flow rate on flowmeter with CO2 liquefaction system.

Technical Specifications

Extraction vessel(s)
Number of vessels 1
Working volume of one vessel 1 L
Maximum operating temperature +70 °C, optionally up to 200 °C
Maximum operating pressure 345 bar (optionally up to 700 bar)
Test pressure 580 bar
Material Stainless steel (AISI 316L)
Separators for fractionation
Number of separators 2 (optionally 3)
Working volume of one separator 300 mL
Maximum operating temperature +70 °C
Maximum operating pressure SP-1 = 200 bar (adjustable), SP-2 = 100 bar
Test pressure 350 bar (or 160 bar for a working pressure of 100 bar)
Material Stainless steel (AISI 316L)
High pressure pump
Maximum CO2 mass flow rate 100 g/min at MAWP
Pump type Dual-stage piston gas booster with steel (CK-45) housing and pneumatic drive (for up to 345 bar), or a hydraulic pump with fluid reservoir (for pressures higher than 345 bar).
Heating block
Electric resistance heater 1.5 kW (or 4.5 kW for a maximum temperature of 200 °C)
Cooling unit (chiller)
Recirculating chiller, cooling power 1000 kcal/hr
Type of heat exchanger Tubular
Power requirements
Supply 220 V, single phase (6 kW)
Energy and CO2 consumption
Average power usage 4 kWh
Average CO2 usage ≤150 g per extraction cycle (CO2 recovery efficiency 90–95%)
Automatic back pressure regulators (aBPR)

The CO2 flow rate is precisely controlled by automatic back pressure regulators, reducing potential for operator error. Mass flow rate is monitored by installing the optional Coriolis mass flow meter.

Industrial automation system
PLC The system control panel is used to set and monitor all process conditions of pressure, temperature, solvent and co-solvent supply, pressure reduction and CO2 recycling. The software fully automates the extraction process (including static and dynamic extraction modes) and includes exhaustive routines for emergency shutdown.
Saving process parameters Up to 50 sets of process parameters may be saved into the system memory for rapid reloading.
Co-solvent system
Maximum co-solvent flow rate 30 ± 5 mL/min
Pump type Booster with a maximum working pressure of 360 bar (optionally 720 bar)
Disruption of raw material cells and cell walls via rapid pressure drop

Time-programmable sudden pressure drop during extraction facilitates expansion of CO2 that has penetrated the cells of the raw material. This rapid expansion ruptures cell walls and increases both the recovery of extract as well as the extraction rate.

Technical safety

Potential hazards caused by dangerous increases in pressure, temperature, and/or wear of sealing elements are completely prevented by software using a system of instrumentation and safety valves installed on each high-pressure element. In case of danger, the installation goes into emergency mode and all systems can be turned off using the emergency shutdown button.

Certifications

The system is fully certified under Directive 2006/42/EC and possesses the Conformité Européenne (CE) marking.

Installation & Layout

Compact benchtop laboratory footprint. Installation and training of equipment operators (1 main operator and 1 supporting personnel) may take place at the production site or other location.

Product Comparison Table

Product
Volume

Pressure

Temperature

Separator

CO₂ Flow
SC-500 0.5 L 345 bar +70 °C 2 50 g/min
F-500 0.5 L 345 bar +70 °C 2 50 g/min
SC-1000 1 L 345 bar +70 °C 2 100 g/min
SUPEREX SC-1000 SUB-CRITICAL 1 L 345 bar +70 °C 2 100 g/min
TH-1000 1 L 345 bar +70 °C 2 100 g/min
F-1000
This Product
1 L 345 bar +70 °C 2 100 g/min
SC-2000 2 L 345 bar +70 °C 2 200 g/min
SC-4000 4 L 345 bar +70 °C 2 400 g/min
AERO-1000 1.0 L 345 bar +70 °C 2 100 mL/min
AERO-5000 5 L 345 bar +70 °C 2 500 mL/min